<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.3/metadata.xsd">
    <identifier identifierType="DOI">10.5880/GFZ.4.8.2020.004</identifier>
    <creators>
     <creator>
      <creatorName nameType="Personal">Eggertsson, Guðjón Helgi</creatorName>
      <givenName>Guðjón Helgi</givenName>
      <familyName>Eggertsson</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0002-9946-7422</nameIdentifier>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </creator>
     <creator>
      <creatorName nameType="Personal">Stefánsson, Ari</creatorName>
      <givenName>Ari</givenName>
      <familyName>Stefánsson</familyName>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </creator>
    </creators>
    <titles>
     <title>Temperature and pressure data from permanently installed sensors behind production casing in well RN-15/DEEPEGS/IDDP-2, Iceland</title>
    </titles>
    <publisher>GFZ Data Services</publisher>
    <publicationYear>2021</publicationYear>
    <subjects>
     <subject>permanent temperature and pressure monitoring</subject>
     <subject subjectScheme="NASA/GCMD Earth Science Keywords">EARTH SCIENCE &gt; SOLID EARTH &gt; GEOTHERMAL DYNAMICS &gt; GEOTHERMAL ENERGY</subject>
     <subject subjectScheme="NASA/GCMD Earth Science Keywords">EARTH SCIENCE &gt; SOLID EARTH &gt; GEOTHERMAL DYNAMICS &gt; GEOTHERMAL TEMPERATURE</subject>
     <subject subjectScheme="NASA/GCMD Earth Science Keywords">EARTH SCIENCE &gt; SOLID EARTH &gt; GEOTHERMAL DYNAMICS &gt; GEOTHERMAL TEMPERATURE &gt; TEMPERATURE PROFILES</subject>
     <subject subjectScheme="GEMET - INSPIRE themes, version 1.0">energy &gt; energy source &gt; renewable energy source</subject>
     <subject subjectScheme="GEMET - INSPIRE themes, version 1.0">industrial process &gt; drilling</subject>
    </subjects>
    <contributors>
     <contributor contributorType="ContactPerson">
      <contributorName nameType="Personal">Eggertsson, Guðjón Helgi</contributorName>
      <givenName>Guðjón Helgi</givenName>
      <familyName>Eggertsson</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0002-9946-7422</nameIdentifier>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
     <contributor contributorType="DataCollector">
      <contributorName nameType="Personal">Eggertsson, Guðjón Helgi</contributorName>
      <givenName>Guðjón Helgi</givenName>
      <familyName>Eggertsson</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0002-9946-7422</nameIdentifier>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
     <contributor contributorType="DataCurator">
      <contributorName nameType="Personal">Eggertsson, Guðjón Helgi</contributorName>
      <givenName>Guðjón Helgi</givenName>
      <familyName>Eggertsson</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0002-9946-7422</nameIdentifier>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
     <contributor contributorType="DataManager">
      <contributorName nameType="Personal">Eggertsson, Guðjón Helgi</contributorName>
      <givenName>Guðjón Helgi</givenName>
      <familyName>Eggertsson</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0002-9946-7422</nameIdentifier>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
     <contributor contributorType="ContactPerson">
      <contributorName nameType="Personal">Stefánsson, Ari</contributorName>
      <givenName>Ari</givenName>
      <familyName>Stefánsson</familyName>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
     <contributor contributorType="ProjectLeader">
      <contributorName nameType="Personal">Stefánsson, Ari</contributorName>
      <givenName>Ari</givenName>
      <familyName>Stefánsson</familyName>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
     <contributor contributorType="ProjectLeader">
      <contributorName nameType="Personal">Friðleifsson, Guðmundur Ómar</contributorName>
      <givenName>Guðmundur Ómar</givenName>
      <familyName>Friðleifsson</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0001-9192-0723</nameIdentifier>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
     <contributor contributorType="ProjectManager">
      <contributorName nameType="Personal">Sigurðsson, Ómar</contributorName>
      <givenName>Ómar</givenName>
      <familyName>Sigurðsson</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0001-9572-5327</nameIdentifier>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
     <contributor contributorType="DataCurator">
      <contributorName nameType="Personal">Lipus, Martin Peter</contributorName>
      <givenName>Martin Peter</givenName>
      <familyName>Lipus</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0002-9899-8352</nameIdentifier>
      <affiliation>GFZ German Research Centre for Geosciences, Potsdam, Germany</affiliation>
     </contributor>
     <contributor contributorType="DataCurator">
      <contributorName nameType="Personal">Reinsch, Thomas</contributorName>
      <givenName>Thomas</givenName>
      <familyName>Reinsch</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID">0000-0002-5803-9819</nameIdentifier>
      <affiliation>GFZ German Research Centre for Geosciences, Potsdam, Germany</affiliation>
      <affiliation>Fraunhofer IEG, Fraunhofer Research Institution for Energy Infrastructures and Geothermal Systems IEG, Bochum, Germany</affiliation>
     </contributor>
     <contributor contributorType="ContactPerson">
      <contributorName>Eggertsson, Guðjón Helgi</contributorName>
      <affiliation>HS Orka, Svartsengi, 240 Grindavík, Iceland</affiliation>
     </contributor>
    </contributors>
    <dates>
     <date dateType="Available">2020-06-31</date>
     <date dateType="Collected">2016-09-05/2020-04-31</date>
    </dates>
    <resourceType resourceTypeGeneral="Dataset">Dataset</resourceType>
    <relatedIdentifiers>
     <relatedIdentifier relatedIdentifierType="DOI" relationType="IsDocumentedBy">10.5194/sd-23-1-2017</relatedIdentifier>
     <relatedIdentifier relatedIdentifierType="URL" relationType="IsDocumentedBy">http://europeangeothermalcongress.eu/wp-content/uploads/2019/07/51.pdf </relatedIdentifier>
     <relatedIdentifier relatedIdentifierType="URL" relationType="IsDocumentedBy">https://pangea.stanford.edu/ERE/db/WGC/papers/WGC/2020/21025.pdf</relatedIdentifier>
     <relatedIdentifier relatedIdentifierType="DOI" relationType="References">10.5880/GFZ.6.2.2018.0</relatedIdentifier>
     <relatedIdentifier relatedIdentifierType="DOI" relationType="IsSupplementTo">10.1186/s40517-021-00187-y</relatedIdentifier>
    </relatedIdentifiers>
    <sizes/>
    <formats/>
    <rightsList>
     <rights rightsURI="http://creativecommons.org/licenses/by/4.0/">CC BY 4.0</rights>
    </rightsList>
    <descriptions>
     <description descriptionType="Abstract">Within the H2020 project DEEPEGS, pressure and temperature gauges were installed behind production casing of well RN-15/DEEPEGS/IDDP-2. Here, we publish the available data gathered from cementing the production casing in 2016 until the end of the DEEPEGS project in 2020. 8 thermocouples were installed behind casing at 329.3 m (TC8), 629.3 m (TC7), 929.3 m (TC6), 1529.3 m (TC5), 1829.3 m (TC4), 2129.3 m (TC3), 2329.3 m (TC2) and 2629.3 m (TC1) depths. In addition, a pressure and temperature gauge was installed at 1229.3 m depths (ERE p/T). All depth are measured depth (MD) below ground level. During installation TC3 was damaged. During cementation, all other TCs as well as the ERE gauge were operating. After the end of drilling, subsequently all TCs except TCs 7 &amp; 8 failed. Until April 2020, data can only be reported for the two remaining thermocouples 7 &amp; 8. Before publication, data was manually cleaned for obvious erroneous readings. Therefore, gaps in the data are inevitable and the readings are not fully continuous.      <br/>
     </description>
    </descriptions>
    <geoLocations>
     <geoLocation>
      <geoLocationBox>
       <westBoundLongitude>-22.6789</westBoundLongitude>
       <eastBoundLongitude>-22.6773</eastBoundLongitude>
       <southBoundLatitude>63.8272</southBoundLatitude>
       <northBoundLatitude>63.8277</northBoundLatitude>
      </geoLocationBox>
     </geoLocation>
    </geoLocations>
    <fundingReferences>
     <fundingReference>
      <funderName>Horizon 2020 Framework Programme</funderName>
      <funderIdentifier funderIdentifierType="Crossref Funder ID">http://doi.org/10.13039/100010661</funderIdentifier>
      <awardNumber>690771</awardNumber>
      <awardTitle>DEEPEGS - Development of Deep Enhanced Geothermal Systems for Sustainable Energy Business</awardTitle>
     </fundingReference>
    </fundingReferences>
   </resource>